Vaillant boiler fault codes

F.22This error code indicates a problem with low water pressure in the boiler system. You may need to check the pressure gauge on the boiler and adjust it to the correct level.
F.27This code means that there is a problem with the boiler’s ignition or flame sensing electrode. You may need to clean or replace the electrode, or contact a heating engineer for assistance.
F.28This error code indicates a problem with low water pressure in the boiler system. You may need to check the pressure gauge on the boiler and adjust it to the correct level.
F.32This code indicates a problem with the boiler’s flow sensor. You may need to clean or replace the sensor or contact a heating engineer to diagnose and fix the issue.
F.49eBUS fault – Short circuit on the eBUS, eBUS overload or two power supplies with different polarities on the eBUS
F.52Mass flow sensor connection fault – Mass flow sensor not connected/disconnected, plug not connected or incorrectly connected
F.53Mass flow sensor fault – Mass flow sensor faulty, filter below venturi filter cap wet or blocked, gas flow pressure too low
F.54Gas pressure fault (in combination with F.28/F.29)- No or too little gas supply pressure, gas valve closed
F.56Fault: Mass flow sensor regulation – Gas valve defective, cable harness to gas valve defective
F.57Fault during comfort safety mode – Ignition electrode highly corroded
F.61Fault: Gas valve regulation – Short circuit/short to earth in cable harness for the gas valve Gas valve defective (coils shorted to earth). Electronic defective
F.62Fault: Gas valve switch-off delay – Delayed shutdown of gas valve. Delayed extinguishing of flame signal. Gas valve leaking Electronics defective
F.63EEPROM error – Electronics defective
F.64Electronics/NTC fault – Supply or return NTC short circuited, electronics defective
F.65Electronic temperature fault – Electronics overheating due to external influences, electronics defective
F.67Electronics/flame fault – Implausible flame signal, electronics defective
F.68Unstable flame signal fault – Air in gas, gas flow pressure too low, wrong air ratio, condensate route blocked, wrong gas restrictor, ionisation flow interruption (cables, electrodes), flue gas recirculation, condensate route
F.70Invalid device specific number (DSN)- Spare part case: Display and PCB replaced at same time and DSN not set, wrong or missing output range coding resistor
F.71Flow NTC fault – Flow temperature sensor signalling constant value: Flow temperature sensor incorrectly positioned at supply pipe. Flow temperature sensor defective
F.72Flow/return NTC fault – Flow/return NTC temperature difference too great → flow and/or return temperature sensor defective
F.73Water pressure sensor signal in the wrong range (too low) – Interruption/short circuit of water pressure sensor, interruption/short circuit to GND in supply line to water pressure sensor or water pressure sensor defective
F.74Water pressure sensor signal outside correct range (too low) – Cable to water pressure sensor has short-circuited at 5V/24 V or internal fault in water pressure sensor
F.75Fault, no pressure change detection when starting pump – Water pressure sensor and/or pump defective, air in heating installation, too low water pressure in boiler; check adjustable bypass, connect external expansion vessel to return
F.76Overheating protection on primary heat exchanger has responded – Cable or cable connections for safety fuse in primary heat exchanger or primary heat exchanger defective
F.77Flue non-return flap/condensate pump fault  No response from flue non-return flap or condensate pump defective
F.78Interruption to DHW outlet sensor at external controller -UK link box is connected, but hot water NTC not bridged
F.83Flow and/or return temperature sensor temperature change fault   – When the burner starts, the temperature change registered at flow and/or return temperature sensor is non-existent or too small. Not enough water in the boiler. Flow and/or return temperature sensor not in correct position at pipe
F.84Fault: Flow/return temperature sensor difference implausible  – Flow and return temperature sensors return implausible values. Flow and return temperature sensors have been inverted. Flow and return temperature sensors have not been correctly fitted
F.85Fault: Flow and return temperature sensors incorrectly fitted- Flow and/or return temperature sensors have been fitted to the same pipe/wrong pipe
F.92Coding resistor fault- The coding resistor on the PCB does not match the entered gas family. Check the resistor, repeat the gas family check and enter the correct gas family.
F.93Gas group fault- Combustion quality outside the permitted range: Wrong gas restrictor, recirculation, wrong gas family, internal pressure measuring point in venturi blocked (do not use lubricant on O-ring in venturi.). Gas family check prematurely terminated.

It’s important to note that these codes may vary depending on the specific model of Vaillant boiler you have. Always refer to your boiler’s user manual or contact a qualified heating engineer if you are unsure about any error codes on your boiler.